    Rosemount 8800 Series Vortex Flow Meters offer world-class reliability with a gasket-free, non-clog meter body that eliminates potential leak points, resulting in maximum process availability and fewer unscheduled shutdowns. The unique design of Emerson's Rosemount 8800 Vortex Flow Meters features isolated sensors that eliminate the need to break process seals for flow and temperature sensor replacement.

    Products

    Search
    1-10 of 28 results for Products

    Specifications

    Flow Meter Accuracy
    ± 0.65% of volumetric rate for liquids
    ± 1% of volumetric rate for gas and steam
    ± 0.70% of mass flow rate in water using MultiVariable option
    ± 2% of mass flow in steam using MultiVariable optio
    Turndown
    38:1
    Output
    4-20 mA with HART® 5 or 7
    4-20 mA with HART® 5 or 7 and Scalable Pulse Output
    FOUNDATION; fieldbus ITK6 with 2 Analog Input blocks, 1 Backup Link Active Scheduler function block, and 1 Integrator function block (1 PID function blo
    Wetted Material
    Stainless Steel – 316/316L and CF3M
    Nickel Alloy – C-22 and CW2M
    High Temp Carbon Steel – A105 and WCB
    Low Temp Carbon Steel – LF2 and LCC
    Duplex UNS S32760 and 6A
    Consult factory for other wetted material
    Flange Options
    ANSI Class 150 to 1500
    DIN PN 10 to PN 160
    JIS 10K to 40K
    Flanges are available in a variety of facings
    Consult factory for additional flange ratings
    Operating Temperatures
    -330°F to 842°F (-200°C to 450°C)
    Line Size
    Flanged: ½-in to 12-in (15 to 300 mm)
    Wafer: ½-in to 8-in (15 to 200 mm)
    Dual: ½-in to 12-in (15 to 300 mm)
    Reducer: 1-in to 14-in (25 to 350 mm)

    Features

    • An isolated sensor allows for inline replacement without breaking the process seal
    • Increase plant availability and eliminate potential leak points with a unique gasket-free meter body design
    • Eliminate downtime and maintenance costs associated with plugged impulse lines with a non-clog meter body design
    • Achieve vibration immunity with a mass balanced sensor and Adaptive Digital Signal Processing with visual filtering
    • A standard internal signal generator included in every meter simplifies electronics verification
    • All meters arrive pre-configured and hydrostatically tested, making them ready and easy to install
    • Simplify SIS compliance with available dual and quad Vortex flow meters
    • Detect liquid to gas phase change using Smart Fluid Diagnostics